Slip sills have no lugs and the lengths are figured 1/2" less than the brick masonry opening. This allows for a 1/4" joint at each end of the sill when pointing is desired.
Figure sill lengths 3/4" less than masonry opening when sealants are desired. This provides 3/8" joint for gun-in of sealant. Always prime joints prior to application of sealant.
Only the ends of lugged sills shall be embedded in mortar; balance of bed joint is left open and tuck pointed later. This prevents cracking of sills from future wall settlement.